Procedure for Restoring Normal Tevatron
Operation After a Camac Card Replacement
Jerry Annala
October 31, 2002
Any 46x card replacement requires a reload from C49. If the card is a 460 that controls a correction dipole, an additional from TOP (currently page C50) is required.
In these instructions, "->" means to select menu item.
Generic 46x replacement:
Go to C49 -> Adjust Active
->Commands->setup 46x's->reload 46x's->reload 46x's for group->select appropriate group
This should configure the cards in the group, and load all of the necessary tables with values. If this card is not a dipole corrector, things should be ready for operation.
Reloading a 460 dipole controller:
Go to C49 -> Adjust Active
->Commands->setup 46x's->reload 46x's->reload 46x's for group->select appropriate group
The dipoles are arranged in groups as follows:
B0 HOR Dipole Corr: HA38 through HB22 (including C:HA48 and C:HB12)
B0 VER Dipole Corr: VA37 through VB21 (including C:VA48)
D0 HOR Dipole Corr: HC38 through HD22 (including C:HC48 and C:HD12)
D0 VER Dipole Corr: VA37 through VB21 (including C:VA48)
F0 HOR Positions: HE44 through HF22
F0 VER Positions: VE43 through VF21
Arc HOR Dipole Corr: T:E0DOG plus all horizontal correctors not listed above.
Arc VER Dipole Corr: All vertical correctors not listed above.
After the C49 reload is complete, reload the most recent TOP save file.
Go to TOP -> dfg save/resto -> RESTORE DFG FROM FILE -> select most recent save file.
The order is important. The C49 reload is done before the restore from TOP.
TOP does not use the dipoles listed in parenthesis, so a full reload must be done from C49 BEFORE a restore from TOP. Also, TOP does not know about injection ramps on the F0 dipoles. The only place these tables are saved is in C49.