Tevatron Tune Measurement System

Short Help

Starting

The tune measurement system is started with C42. There can only be one copy of C42 running at any time. On startup, the message must be "Connecting to VXI Slot 0 controller. Connection OK" otherwise, you may need to reboot the VXI Slot 0 controller at E0.

Autozero and Kicker Poweramps

On startup, the autozero and poweramps are always *off*. Goto Windows->Autozero Control to bring up the Autozero Control page. Click on the buttons to turn them on. Note that the tune system will not work if the autozero boxes are off. When C42 is exited, they are automatically turned off again. If C42 crashes goto T9 -> dampers page 2 and turn them off manually. T:MOTOR3->0, T:MOTOR23->0 and T:VTICK and T:HTICK to off.

Move overall Trigger timing

To move the overall trigger timing goto Configuration->Startup ...
The overall triggers for p's are moved by setting "measured p bunch offset". The pll trigger is moved by setting "measured pbar bunch offset" at this time. Click "OK" to send the new offsets to the VXI crate. These settings are automatically saved when C42 exits or the user can force a save using Configuration->Save.

Reboot VXI controller

Goto EO. The VXI crate is in the crate labelled "???". Wake up the Mac on the left of the crate. Hit the reset and abort buttons until the Mac shows that the VXI crate is rebooting. After reboot is done, i.e. when "->" prompt is shown, make sure that the LEDs on the Slot 0 controller are lit exactly as shown. If not, hit the RST button on the DSP card until the leds are lit as shown. Start the VxWorks application by typing "sp Server" on the Mac.

 